Springwood Corridor

5G NR n3 / n28 — Drive Test Report

SEQ Coverage Verification  |  Job JOB-2026-0421

Project Information

Project NameSEQ Coverage Verification
Job IDJOB-2026-0421
Site NameSpringwood Corridor
Revision / Amendment1 / 0
AuthorRF Survey Team
Surveying CompanyYour Survey Co.
Report Generated2026-07-16 10:21
Survey Date2026-04-21 08:46 → 2026-04-21 09:16
Survey TypeDrive
HW ToolCellScout
Technicianaaa
IMSI505038349450043
OperatorVodafone AU
Bands SurveyedNR5G BAND 28, NR5G BAND 3
Total Samples1,765
Source Data FileVodafone_PCID_751157484_260401.xlsx (SHA-256 2318ca03445203b0…)

RF Statistics Summary — 5G (FDD NR5G)

MetricSamplesMinMaxAverageStd DevKPI
RSRP1,765-129.00 dBm-64.00 dBm-90.80 dBm11.38 dBm55.01% > -95 dBm
SINR1,7650.00 dB23.00 dB12.02 dB3.00 dB87.99% > 8 dB
RSRQ1,765-29.00 dB-11.00 dB-13.45 dB2.33 dB—

Serving Cell Information

PCICell Global IDChannelBandSamplesShare %Avg RSRPAvg SINR
3405F53002C7240EB366290NR5G BAND 338621.9-82.3 dBm13.5 dB
3205F53002C7240E9366290NR5G BAND 334619.6-79.5 dBm12.9 dB
73305F53002CE380E8366290NR5G BAND 330417.2-101.7 dBm9.5 dB
56605F53002CC5C0EC366290NR5G BAND 326515.0-96.3 dBm13.7 dB
74205F53002CE040EB366290NR5G BAND 318410.4-89.5 dBm11.7 dB
18105F53002D4200E8366290NR5G BAND 31005.7-99.8 dBm10.4 dB
73505F53002CE380EA366290NR5G BAND 3522.9-96.6 dBm10.1 dB
74105F53002CE040EA366290NR5G BAND 3341.9-99.2 dBm11.5 dB
69205F53002D0380E9366290NR5G BAND 3261.5-98.2 dBm11.8 dB
73905F53002CE040E8366290NR5G BAND 3241.4-105.9 dBm8.8 dB
70605F53002CF400EB366290NR5G BAND 3160.9-100.0 dBm9.5 dB
21605F53002CE0403D159130NR5G BAND 28140.8-113.0 dBm7.4 dB

Coverage Plots — 5G