- FTTx power meter for B/E/G-PON applications
- ONU and OLT test ports with pass-through design
- Fixed SC/APC Interface for ONU and OLT test ports
- Concurrent measurement and display of Upstream and Downstream signals
- 1310 nm Upstream CW/Burst signal support
- 1490/1550 nm Downstream signal support
- Programmable thresholds with Pass/Fail indication
- Optional broadband power meter with universal adaptors
- Up to 1920 measurements
- USB (wired) or optional Bluetooth (wireless) interface for test result transfer
- PC software for data transfer, management and report generation
- Splash and dust resistant keypad and chassis design
- Upload of stored results to VeEX R-Server workforce management system or Fiberizer Cloud
- High contrast LCD – visible outdoors, backlight for indoor or low light conditions
FX80 PON Optical Power Meter
PON Optical Power Meter
FX80 PON Optical Power Meter is an in-Line optical power meter geared for FTTx/PON service activation. It simultaneously measures downstream signals to the ONT and upstream signals to the OLT.
Fiberizer™ software for Windows® Desktop, Android™, and/or Apple® mobile devices is available to assist in data transfer, record management, and report generation for various VeEX fiber optics testers.
- FTTx power meter for B/E/G-PON applications
- ONU and OLT test ports with pass-through design
- Fixed SC/APC Interface for ONU and OLT test ports
- Concurrent measurement and display of Upstream and Downstream signals
- 1310 nm Upstream CW/Burst signal support
- 1490/1550 nm Downstream signal support
- Programmable thresholds with Pass/Fail indication
- Optional broadband power meter with universal adaptors
- Up to 1920 measurements
FX80 Replaced with FX81
- Wavelength-selective level measurements for verifying B/E/GPON networks according to ITU-T G.983/4 and IEEE 802.3ah recommendations
- Calibrated wavelengths: 1310/1490/1550 nm
- FTTx PON Power Measurement range (Passthrough):
-40 to +10 dBm (1310 nm)
-40 to +12 dBm (1490 nm)
-40 to +25 dBm (1550 nm) - Burst measurement range @ 1310 nm: -35 to +10 dBm
- Pass Through Insertion Loss: ≤ 1.5 dB
- BB-OPM Absolute Accuracy: ± 0.5 dB
- Linearity: ± 0.2 dB @ 1550 nm (≥ -40 dBm)
- Optical Return Loss @ 1550 nm: ≥ 55 dB
- Display resolution: 0.01 dB
- Broadband (CW) measurement range:
– Standard (PM1) version: -65 to +10 dBm
– High (PM2) version: -50 to +25 dBm - Battery: Built-in, rechargeable Li-Polymer
- Battery operating time (without backlight):
– Broadband OPM mode: > 80 hours
– FTTx PON mode: > 40 hours