The Kurth Electronic Copper Testing (KECT) module with its improved interference immunity is the ideal measuring tool for technicians testing, troubleshooting and qualifying performance parameters of copper pairs of traditional and modern broadband access systems.
As an optional module for the powerful xDSL MULTITEST test equipment family the Copper Test module allows an accurate analysis and a complete overview of transmission parameters as well as the physical assessment of copper lines under test.
KE3550 Access and Loop Tester (xDSL/ISDN/Copper/+more)
KE3700 CT Telco Loop Qualifier Specialized for qualification of telecommunications applications up to 31 MHz.
Fault analysis of AC/DC applications with for telephone 2-wire lines designed multimeter functions. Precise fault detection and localisation with the TDR function.
Line Multimeter
- Voltage AC/DC incl. AC frequency
- Resistance, line resistance and resistance line balanced
- Insulation and leakage
- Capacitance and capacitance balanced
- Ground resistance
- LCL Balance @ 1 MHz
- NEXT @ 1 MHz
- PPA and signature detection
- Current AC/DC
31 MHz HF Line Measurements
- Spectrum analysis, impedance and return loss (graphical)
- LCL balance and NEXT
- Receive signal (graphical) and signal level transmitter
- Wideband and impulsive noise
Cable Length Measurement
- Distance to short (resistance) and distance to opens (capacitance)
- TDR function with graphical cable fault detection
- NEW: xTalk measurement
Automated Line Measurements
- Configurable test scenarios
- With or without far end devices (e.g. KE905)
Cable Type Database
- Editable cable parameters
- Database with hundreds of cable types
KECT & KE3700 CT: 31 MHz Line Qualification | |
---|---|
General | Frequency range: 4,312 kHz up to 31 MHz manual entry or xDSL Bandwith Input impedance 100 Ω, 120 Ω Velocity of propagation 0,33 to 3,33 10 mV DC Cable parameter diameter 0,1 to 1,6 mm |
Impedance | Output value: 0 … 1000 Ω, graphical Resolution / Accuracy: 0,1 Ω / ± 5 % or ± 5 Ω |
Return Loss | Output value: 0 … 100 dB, graphical Resolution / Accuracy: 0,01 dB / ± 1 dB |
LCL (Balance) | Output value: 0 … 110 dB, graphical Resolution / Accuracy at 2 MHz / 10 MHz / 30 MHz: 0,01 dB / ± 0,5 dB / ± 2 dB / ± 5 dB |
NEXT | Output value: 0 … 130 dB, graphical Resolution / Accuracy: 0,01 dB / ± 0,5 dB |
Receive Level (high impedance) | Output value: -100 … 10 dBm, graphical Resolution / Accuracy: 0,01 dBm / ± 1 dBm |
Spectrum (high impedance) | Output value: -150 … 10 dBm or -150 … 10 dBm/Hz, graphical Resolution / Accuracy: 0,01 dBm / 0,01 dBm/Hz / ± 1 dBm |
Wideband Noise | Filter: ADSL 1,2 to 1,5 MHz / ADSL 2+ 3,0 MHz / VDSL2 8abcd to 9,0 MHz / VDSL2 12ab to 13,0 MHz / VDSL2 17a to 19,0 MHz / VDSL2 30a to 31,0 MHz Output value: dBm, numeric Resolution / Accuracy: 0,01 dBm / ± 1 dBm |
Impulse Noise | Pulse duration:> 500 µs Threshold : 0,1 mV to 25,4 mV / -20 to -59,9 dB Resolution: 0,1 mV / 0,1 dB Other displayed values: Runtime in seconds / Counter of noise pulses Measuring time: unlimited |
KECT & KE3700 CT: General Information | |
---|---|
Connections | 2 x 4 mm banana jacks (Line1 and Line2) for 3 pole for TF plug, non-contact protection RJ45 100 Mb Management Port |
Operating temperature | 0 °C to +50 °C |
Storage temperature | -10 °C to +60 °C |
Humidity | Up to 93%, non-condensing |
KECT & KE3700 CT: Line Multimeter | |
---|---|
General | Overload protection with switching over to voltage measurement Test lead compensation Probing between A-B, A-GND and B-GND Min-Max-Values |
DC Voltage | Measuring range: 0 to 280 V DC Resolution / Accuracy up to 6 V: 1 mV DC / ± 0,5 % + 2 digits Resolution / Accuracy up to 60 V: 10 mV DC / ± 0,5 % + 1 digit Resolution / Accuracy up to 280 V: 100 mV DC / ± 0,5 % + 1 digit Overload protection: 300 V DC |
DC Current | Measuring range: 0 to 700 mA DC Resolution / Accuracy: 0,1 mA / ±0,5% + 3 digits Overload protection: 950 mA |
AC Voltage | Measuring range: 0 to 200 V AC sinusoidal Resolution / Accuracy up to 6 V: 1 mV DC / ± 1,5 % + 3 digits Resolution / Accuracy up to 60 V: 10 mV DC / ± 1,5 % + 3 digits Resolution / Accuracy up to 280 V: 100 mV DC / ± 1,5 % + 3 digits Overload protection: 300 V AC sinusoidal |
AC Frequency | Measuring range: 15 Hz to 60 kHz Resolution / Accuracy up to 600 Hz: 0,01 Hz / ± 0,5 % + 1 digit Resolution / Accuracy up to 6 kHz: 0,1 Hz / ± 0,5 % + 1 digit Resolution / Accuracy up to 60 kHz: 1 Hz / ± 0,5 % + 1 digit |
AC Current | Measuring range: 0 to 500 mA AC Resolution / Accuracy: 0,1 mA/ ±1,5% + 5 digits Overload protection: 950 mA |
Isolation / Resistance (stress / leakage) | Measuring range: 1 kΩ to 50 MΩ at 8 V test voltage / 60 kΩ to 2 (5) GΩ at 100 V test voltage Resolution / Accuracy up to 30 MΩ: 10 kΩ / ± 2 % + 50 kΩ Resolution / Accuracy up to 300 MΩ: 100 kΩ / ± 2 % + 500 kΩ Resolution / Accuracy up to 3 GΩ: 1 MΩ / ± 2 % + 5 MΩ |
Resistance Loop | Measuring range: 0 to 3 kΩ with DC line voltage suppression Resolution / Accuracy: 100 mΩ / ±0,5% + 0,5 Ω Loop length (Short) calculation: 0,1 m to > 20 km depending on cable parameter settings Loop length resolution / Accuracy: 0,1 m / ±1% |
Resistance | Measuring range: 0 to 2 MΩ Resolution / Accuracy: 4 digits / ±1% |
Capacitance | Measuring range: 0 to 3 µF (10 µF) Resolution / Accuracy up to 30 nF: 10 pF / ±1% + 100 pF Resolution / Accuracy up to 300 nF: 100 pF / ±1% + 500 pF Resolution / Accuracy up to 3 µF: 1 nF / ±1,5% + 5 nF Opens calculation: 0,1 m to > 20 km depending on cable parameter settings Opens resolution / Accuracy up to 100 m: 1 mm / ±1% Opens resolution / Accuracy up to 1 km: 0,1 m / ±1% Opens resolution / Accuracy > 1 km: 1 m / ±2% |
Ground Return Resistance (Station Ground) | Measuring range: 0 to 2 MΩ Resolution / Accuracy: 4 digits / ±1% |
LCL Balance @ 1 MHz | Measuring range: 0,01 to 90 dB Resolution / Accuracy: 0,01 dB / ±0,5 dB |
NEXT @ 1 MHz | Measuring range: 00,1 to 125 dB Resolution / Accuracy: 0,01 and 0,1 dB / ±0,5 dB |